You and the process

With a person
Anna, in-house recruiter
9 years hiring engineers
30 minutes with a real recruiter
They read your CV with you, on a call, and say where the offers are being lost.
Didn’t find what you were looking for? Tell us what to build
GE Vernova

Lead Control Automation System Engineer

  • Hybrid
  • 6+ years

Salary

Not stated

Similar roles pay £115K - 150K a year · our estimate

AI summary

For members

The whole posting in a few lines. Sign up to read it here and on every role you open.

Sign Up to Read

Description

The team sits within the global HVDC Centre of Excellence in Grid Integration, based in Stafford, and works on the Green Energy transition.

The role leads the requirements, design, implementation and development of the digital control system for HVDC Control and Protection, working across HVDC engineering disciplines and with the solution and engineering centre (NPI, ITO, OTR and Product Care).

You will also develop engineering talent, manage engineering processes, guide technical decisions and deliver technical solutions that meet NPI, project delivery and tender goals.

The work covers IEC 61850 architecture, cybersecurity integration, Factory Acceptance Testing (FAT) and site commissioning.

The company wants a hands-on technical leader with substantial, proven experience in control and protection design, deep IEC 61850 configuration and SCL file generation skills, knowledge of industrial networking (Layer 2 and Layer 3 protocols), and a record of mentoring engineers and delivering complex power system projects on time and within budget.

The role is hybrid, with 3 days onsite in Stafford required.

Relocation assistance is not provided.

Responsibilities

  • Lead requirements definition, design, implementation and testing of digital control systems for HVDC Control and Protection, including network and cybersecurity architecture.
  • Oversee LAN and communication architecture design, including configuring industrial Ethernet switches, routers and satellite clocks.
  • Define and analyse main I/O lists and signal interfaces so the HVDC Control System, Balance of Plant (BoP) equipment and SCADA systems are fully compatible.
  • Work with New Product Introduction (NPI) teams to configure Remote Terminal Units (RTUs), Bay Controllers (BCUs) and Merging Units for signal acquisition in digital substations.
  • Coach and develop engineering team members and provide technical leadership.
  • Lead configuration of IEC 61850 IEDs with vendor tools and System Configuration Tools for full system integration.
  • Lead generation of Substation Configuration Description Language (SCL) files.
  • Apply sequencing and interlocking principles in substation automation, and implement them on IEC 61850 IEDs.
  • Define control panel requirements and produce detailed design documents with standard design blocks and tools such as Engineering Base, covering panel electrical schematics, wire and cable schedules, routine test specifications, general assembly drawings and Bill of Materials (BOM).
  • Ensure work follows departmental design standards, engineering reviews and quality guidelines.
  • Lead testing, debugging and analysis of complex IEC 61850 communication systems using tools such as IEDScout and Wireshark.
  • Oversee hardware design, configuration and testing so the HVDC Control System is delivered on schedule and within budget.
  • Oversee Factory Acceptance Testing (FAT) and lead customer witness testing.
  • Support site teams with installation, commissioning and troubleshooting.
  • Prepare and present Substation Control System information to internal and external stakeholders.
  • Review and approve design documents, keeping deliverables high quality, cost-effective and on time.
  • Improve products and processes continuously for delivery speed, stability and reliability.
  • Keep technical data for assigned projects documented and managed in line with engineering policies and procedures.

Requirements

  • A bachelor's or master's degree in Electrical or Electronics Engineering, or a related technical field.
  • Substantial, progressive experience in control and protection system design and substation automation.
  • Strong background in configuring Substation Bay Controllers, Merging Units, IEC 61850 IEDs and HMI/SCADA technologies.
  • In-depth knowledge of industrial communication networks, Ethernet-based protocols and control and protection relay logic design.
  • Strong working knowledge of industrial and utility electrical control systems, Digital Control Systems (DCS) and substation automation.
  • Solid understanding of communication network security, hardening and cybersecurity best practices.
  • Excellent knowledge of Layer 2 and Layer 3 protocols, such as IPv4, OSPF, LACP, DMZ, VPN, DNP3, IEC 60870-5-104 and Modbus.
  • Proven technical leadership in a complex systems engineering environment, with the ability to make decisions independently, bring in cross-functional experts and deliver on schedule.
  • Strong written and spoken communication skills, with the ability to build open dialogue, share engineering knowledge and explain complex ideas clearly to customers and leadership.
  • A analytical approach with a record of troubleshooting complex technical issues and beating reliability, quality and cost targets.

Conditions

Hybrid working with 3 days onsite in Stafford required.

The role offers a large degree of flexibility in work arrangements.

Relocation assistance is not provided.

Equal opportunity applies.

Benefits

  • Competitive benefits.
  • Strong development opportunities.
  • Work in an international team within the global HVDC Centre of Excellence in Grid Integration, based in Stafford.

Where you’d work

Part of the week in the office

You can work from

  • United Kingdom

No relocation

About the company

GE Vernova

  • Industry: Climate

Office in United Kingdom

Also hiring in Houston, United States, United States, Bucharest, Romania and 24 more places

28 of their 141 open roles are remote

Your chances

Worth a look before you spend an evening tailoring a CV for it.

  • 19 checks run
  • 1 red flag

Still hiring?

13 checks

1 red flag

How crowded?

6 checks

No red flags

Fits Me

How well does this role fit you?

Answer a few questions or drop your CV, and every role gets a fit score with the reasons, this one first.

  • Your field
  • Level
  • Stack
  • Work model
  • Salary floor
  • Must-haves
Details12 facts · Role, Location, Compensation, Employment, Company
Seniority
Lead
Type
Full-time
Industry
Climate
Region
United Kingdom
Pay period
Annual
Show 7 more factsShow less

Role

Category
Development
Seniority
Lead
Experience
6+ years

Location

Work model
Hybrid
Region
United Kingdom
Office
  • United Kingdom
Remote from
  • United Kingdom
Relocation
Not offered

Compensation

Salary
Salary by agreement
Pay period
Annual

Employment

Type
Full-time

Company

Industry
Climate

Something wrong with this vacancy?

Similar vacancies

Share this vacancy

What's wrong with it?

The employer never sees who reported.

Reason